XICHI pitches custom medium-voltage soft starters for heavy industrial loads

Oct. 24, 2026
XICHI pitches custom medium-voltage soft starters for heavy industrial loads
By AI, Created 17:20 UTC, Oct 24, 2026, AGP -

Xi'an XICHI Electric Co., Ltd. outlined how its CMV series medium-voltage solid-state soft starters are designed to handle high-inertia motors in mines, steel plants and petrochemical facilities. The company says the platform combines digital control, bypass contactors and configurable protection to reduce grid stress and mechanical wear.

Why it matters: - Heavy industrial plants need motor starters that can manage high starting torque without damaging equipment or destabilizing weak power grids. - The wrong starting method can create voltage sags, trigger protective relays and accelerate wear in shafts, gearboxes and couplings. - XICHI is positioning its custom medium-voltage soft starters as a lower-complexity option when fixed-speed operation is enough and variable frequency drives are not required.

What happened: - Xi'an XICHI Electric Co., Ltd. said its CMV series medium-voltage solid-state soft starter is built for demanding loads such as mine exhaust fans, blast furnace blowers and petrochemical centrifugal compressors. - The company described the product as a custom-engineered solution for specific load profiles and site constraints. - XICHI directed engineers and facility managers to review technical documentation and submit motor parameter requirements through its official website: More information.

The details: - The CMV series uses a 32-bit ARM microprocessor to process system signals and control phase firing angles in real time. - Fiber-optic driver technology separates the high-voltage power circuit from the low-voltage control unit. - The power stage uses series-connected silicon-controlled rectifiers. - For 3 kV systems, the thyristor bridge uses 12 thyristors per phase. - For 6 kV systems, the thyristor bridge uses 18 thyristors per phase. - For 10 kV systems, the thyristor bridge uses 30 thyristors per phase. - Dynamic and static voltage equalization networks are built into the thyristor assembly to distribute voltage evenly during switching. - The CMV series includes a direct-start capacity vacuum bypass contactor. - The bypass contactor takes the thyristor stack offline after the motor reaches full speed to reduce heat generation and improve steady-state efficiency. - XICHI says the CMV series includes a patented heatsink design to improve heat dissipation, reduce thermal stress and extend service life. - Communication interfaces include Modbus RTU, Modbus TCP and RS485. - A centralized PLC or DCS can manage up to 31 starters on a single bus line. - The CMV series includes eight configurable protection functions: phase loss, overcurrent, phase current imbalance, thermal overload, underload or dry run, start timeout, overvoltage and undervoltage, and ground fault detection. - Operators can adjust protection thresholds through the digital control interface. - The system is designed for ambient temperatures from -20°C to +50°C. - Installations up to 1,500 meters above sea level can operate without capacity derating. - Above 1,500 meters, the equipment requires calculated derating to account for lower air density.

Between the lines: - The product strategy centers on application-specific engineering rather than a one-size-fits-all starter. - XICHI is emphasizing customization across power hardware, cabinet layout, control software and communications to fit existing plant automation systems. - The article frames medium-voltage soft starters as a practical middle ground between direct-on-line starting and variable frequency drives for fixed-speed industrial loads. - The customization model also reflects the realities of industrial sites, where installation space, environmental conditions and control-system integration vary widely.

What's next: - XICHI says its customization process begins with evaluating motor torque curves, grid capacity and site environment conditions. - The company expects customers to use its modular platform to specify voltage level, enclosure rating, heat dissipation requirements and automation interfaces. - Future deployments will likely focus on integrating the starters into existing SCADA and PLC frameworks with minimal commissioning overhead.

The bottom line: - XICHI is betting that tailored medium-voltage soft starters can solve heavy-load starting problems more efficiently than generic equipment, especially where grid stability, thermal management and plant integration are critical.

Disclaimer: This article was produced by AGP Wire with the assistance of artificial intelligence based on original source content and has been refined to improve clarity, structure, and readability. This content is provided on an “as is” basis. While care has been taken in its preparation, it may contain inaccuracies or omissions, and readers should consult the original source and independently verify key information where appropriate. This content is for informational purposes only and does not constitute legal, financial, investment, or other professional advice.

Sign up for:

The Green Earth Gazette

The daily local news briefing you can trust. Every day. Subscribe now.

By signing up, you agree to our Terms & Conditions.

Share this page:

Advanced Search Options

Search for:

Search scope:

Type:

Search in:

Date range:

The last

Sort by:

Sign up for:

The Green Earth Gazette

The daily local news briefing you can trust. Every day. Subscribe now.

By signing up, you agree to our Terms & Conditions.